logo
Shenzhen AWTSW Electronic Technology Co.,Ltd
0086-13959254228

Regenerative Battery Charging And Discharging Tester 200V 150A 30CH

Regenerative Battery Charging And Discharging Tester 200V 150A 30CH
Place of Origin:CHINA
Brand Name:AWT
Certification:As required
Model Number:RCDS-200V150A
Minimum Order Quantity:1Send an Inquiry
Price:Send an Inquiry
Standard Packaging:Standard Export Wooden Case Packaging
Delivery Time:7-10 Days
Payment Terms:T/T
Supply Ability:50sets per month
Product Details
RCDS-200V150A: High-power Charge And Discharge Testing For Lithium Battery Cells And Packs.
0.5‰ High-Precision Calibration: High-precision Voltage And Current Calibration For Accurate Test Results.
Smooth CC/CV Transition: Four-wire Sensing And Soft-start Control For Stable Charging.
Intelligent Precision Ranging: Automatic Range Switching Maintains Accuracy Across Different Test Stages.
Modular Channel Configuration: Flexible Channels Support Independent Configuration And Parallel Operation.
Real-Time Temperature Protection: Continuous Battery Temperature Monitoring Enhances Testing Safety.
Advanced Thermal Management: Dual-fan Forced Cooling Supports Stable Long-term Operation.
Multi-Battery Compatibility: Adjustable Fixtures Accommodate Different Cell And Battery Pack Formats.
Product Description
Detailed Specifications & Features

Regenerative Battery Charging and Discharging Tester – 200V 150A – 30CH

Model:RCDS-200V150A

Application:

Circle Life Testing and quality control in Battery mass production or Lab including lithium ion batteries, lead-acid batteries, cadmium-nickel batteries and nickel-hydrogen batteries

Function:

  • Cycle life test
  • Capacity test
  • Charging characteristics test
  • Discharge characteristics test
  • Charge retention capacity test
  • Charge and discharge efficiency test
  • Overcharge over discharge rate endurance test
  • MES Server Compatibility

Environmental Requirements and Technical Parameters

  • Ambient humidity: no more than 85% R.H (no water vapor condensation)
  • No strong vibration, corrosive gases and flammable and explosive gases exist in the environment.
  • Resolution: AD: 16bit; DA: 16bit
  • Power Supply: AC Voltage 380V + 10%, Frequency: 50 Hz + 5%.

Specification

  Model RCDS-200V150A
1 Main channel 30 CH
2 Channel Action mode Independence
3 Main Channel Working Mode Charging: constant current charge CC, constant voltage charge CV, constant current charge CCCV.
No impulse voltage and current should be realized In the process of constant current and constant voltage charging
Discharge: constant current discharging CD, constant power discharging CP, constant resistance discharging CR; stationary;
Main Channel Test Termination Conditions Time, total voltage, total current, capacity, - V, Vcell, RSOC, etc.
4 Main channel voltage Single channel measurement range 0V-200V
Minimum discharge voltage 6V(Port voltage)
Accuracy ±(0.05%FS+0.05%RD)
Resolution 1mV
Main channel current Single channel measurement range ±150A
Minimum output current 30mA
Accuracy ±(0.05%FS+0.05%RD)
Resolution 1mA
Current Start Response Time <10ms
Time Resolution 10ms
Power output power Single Channel Continuous Operating Power 3000W
Stability ±(0.1%FS+0.1%RD)
5 RCDS comm mode   LAN
  BMS Comm   Support CAN2.0A, CAN 2.0B; RS485 communication Support DBC import, realize data reading with BMS CAN, and participate in process control
6 Control program Support data protection when power off, continue testing caused of power cutoff or manually stop and revise step parameter online.
Users can set protection condition, include minimum voltage, maximum voltage, minimum current, maximum current, etc.
Users can set auxiliary channel protection condition, including minimum voltage, maximum voltage, maximum temperature, minimum temperature.
Cycle time Max. 9,999
Programmable step Max. 9,999
Nested loop Max. 10 layers
Step time range No limit, support h, min, s
    Data record Time≥1S, voltage≥1mV, current ≥1mA
Program feature Each step has one or multiple exit
7 Data display Cycle list Circulation number. Charge/discharge capacity, efficiency, power and average voltage, etc.
Process list Process number, working mode, process time, capacity, power, DIR, medium voltage, cut-off voltage, cut-off current, etc.
      Detail list Record number, system time, cumulative time, voltage, current, energy, power, cell temperature, etc.
8 Data export Data can be exported as EXCEL, TXT or diagram. Provide charge discharge efficiency, charge discharge curve, voltage, capacity, current-time characteristic curves, etc.
9 Data saving Save as files
10 Curves type X-coordinate: total time, charge discharge capacity, cycle time
Y-coordinate: total voltage, current, capacity, power, cell temperature
11 Software protection Power off data protection, power resume continue testing, OVP, ODP, OCP, UCP, OTP, capacity protection, abnormal voltage trend protection, abnormal current trend protection, abnormal current fluctuation protection, abnormal voltage fluctuation protection, abnormal charging voltage increase rate protection, abnormal discharge current decrease rate protection
Hardware protection Power off, open circuit and short circuit protection. Reverse or wrong connection protection, OCP, OVP, OTP.
Warning function Switch off automatically under emergency, shutdown when power off, load connect and disconnect automatically.
12 Sampling terminals Four-polar sampling. Crocodile clip or other clips.
13 Energy consumption Discharge power feedback to grid
14 Cooling method Forced Fan-cooled
15 Safety grade In accordance with EN60950, GB4943
Voice Test voice by IEC62040-3 and voice is less than 70dBA. Sound level meter should be accordance with Ⅰtype in IEC804, Accuracy should be better than ±0.5dB.
IP grade IP20
16 Thunder proof Reach GB17626 2-pole lightning protection requirements.
17 Repair Modularized structure. Can be replaced or repair with spare parts. Free during warranty period.
  Software update For lifetime until hardware incompatible.

Feature

  • Energy Feedback (DC Bus Efficiency < 80%): Energy Feedback Type, both charging and discharging are energy-saving, which can save a lot of power consumption.Expenditure, while saving a lot of energy consumption heat generated by air conditioning electricity costs.
  • CCCV charging: CCCV charging process without gap transition, without any voltage and current impact. It can effectively prevent PCB protection action and secondary protection action caused by islanding effect or overshoot phenomenon of pole ear dedusting or micro-short circuit due to heat concentration of peak current.
  • The current and voltage sampling has good stability and high precision: adopting high precision and high dynamic range ADC/DAC unit, the voltage sampling has high precision and good long-term stability.
  • DCIR DC load impedance test function: Real-time detection of the load impedance in MS stage during battery charging/unloading, can intuitively and conveniently identify DCIR unstable batteries.
  • DL dynamic load protection function: effectively protect the battery in charge and discharge, prevent battery ignition and effectively avoid the current shock caused by the loose connector, effectively protect the electronic components of the battery from the impact current damage, such as MOSFET, FUSE.
  • Voltage clamp function: When the battery protection action or equipment is abnormal during charging, the voltage clamp can set the voltage to prevent the damage of the battery or battery protection plate.
  • ECD&EVD Protection: Batteries that can avoid active protection and stop charging or discharging in advance due to unqualified conditions can be selected.
  • The test steps can be divided into sections to set recording conditions and implement intelligent data management and recording.
Message for quick reply