5V 160A Prismatic Cell Charging And Discharge Machine
5V 160A Prismatic Cell Charging And Discharge Machine
Place of Origin:CHINA
Brand Name:AWT
Certification:As required
Model Number:5V160A
Minimum Order Quantity:1Send an Inquiry
Price:Send an Inquiry
Standard Packaging:Standard Export Wooden Case Packaging
Delivery Time:7-10 Days
Payment Terms:T/T
Supply Ability:50sets per month
Product Details
AWT-5V160A-32ch:
High-power Charge And Discharge Testing For Lithium Battery Cells And Packs.
0.5‰ High-Precision Calibration:
High-precision Voltage And Current Calibration For Accurate Test Results.
Smooth CC/CV Transition:
Four-wire Sensing And Soft-start Control For Stable Charging.
Intelligent Precision Ranging:
Automatic Range Switching Maintains Accuracy Across Different Test Stages.
Modular Channel Configuration:
Flexible Channels Support Independent Configuration And Parallel Operation.
Real-Time Temperature Protection:
Continuous Battery Temperature Monitoring Enhances Testing Safety.
Advanced Thermal Management:
Dual-fan Forced Cooling Supports Stable Long-term Operation.
Multi-Battery Compatibility:
Adjustable Fixtures Accommodate Different Cell And Battery Pack Formats.
Product Description
Detailed Specifications & Features
Overview
Prismatic Cell Charging And Discharge Machine
Model: 5V160A
-
- Application: mainly used for circle life testing and quality control of li-ion battery, lead-acid battery, Ni-Cd battery, Ni-MH battery and so on in production line or in lab.
- Support battery circle life testing, capacity testing, charging characteristic testing, discharging characteristic testing, charge retention capability testing, charge and discharge efficiency testing, over charge or over discharge rate affordability testing.
- Working Environment and Technical Parameters
- Power supply: AC 380V±10%, frequency: 50HZ±5%.
- Working temperature: 10 - 45℃.
- Humidity: less than ≤ 85%R.H (non-condensing).
- No severe shake, no corrosive gases, no flammable or explosive gases around.
- Resolution: AD 16 bit, DA16 bit.
- Parameters
| No. | Item | RCDS-5V160A | ||
|---|---|---|---|---|
| 1 | Main channels | 500 CH (MES Server Compatibility) | ||
| 2 | Channels working mode | Independently | ||
| 3 | Main channel working mode | Charge: CC, CV, CCCV, no voltage or current impact when CC transfer to CV Discharge: CD, CP, CR Still | ||
| Main channel test cutoff condition | Time, total voltage, total current, capacity, -ΔV, Vcell, RSOC, etc. | |||
| 4 | Main channel Voltage | Single channel test range | 0V-5V | |
| Min. discharge voltage | 0.1V | |||
| Accuracy | ±(0.05%FS+0.05%RD) | |||
| Resolution | 1mV | |||
| Main channel Current | Single channel test range | ±150A | ||
| Min. output current | 200mA | |||
| Accuracy | ±(0.05%FS+0.05%RD) | |||
| Resolution | 1mA | |||
| Current start response time | <50ms | |||
| Time | Resolution | 100 ms | ||
| Power | Output power | Single channel continuous working power 500W | ||
| Stability | ±(0.1%FS+0.1%RD) | |||
| Auxiliary channel parameter cutoff function | Main channel step can be set to stop or jump when auxiliary channel signal reach to a certain condition. | |||
| 5 | Communication | LAN | ||
| 6 | Control program | Support data protection when power off, continue testing caused of power cutoff or manually stop and revise step parameter online. | ||
| Users can set protection condition, include minimum voltage, maximum voltage, minimum current, maximum current, etc. | ||||
| Users can set auxiliary channel protection condition, including minimum voltage, maximum voltage, maximum temperature, minimum temperature. | ||||
| Cycle time | Max. 9,999 | |||
| Programmable step | Max. 9,999 | |||
| Nested loop | Max. 10 layers | |||
| Step time range | No limit, support h, min, s | |||
| Data record | Time≥1S, voltage≥1mV, current ≥1mA | |||
| Program feature | Each step has one or multiple exit | |||
| 7 | Data display | Cycle list | Circulation number. Charge/discharge capacity, efficiency, power and average voltage, etc. | |
| Process list | Process number, working mode, process time, capacity, power, DIR, medium voltage, cut-off voltage, cut-off current, etc. | |||
| Detail list | Record number, system time, cumulative time, voltage, current, energy, power, cell temperature, etc. | |||
| 8 | Data export | Data can be exported as EXCEL, TXT or diagram. Provide charge discharge efficiency, charge discharge curve, voltage, capacity, current-time characteristic curves, etc. | ||
| 9 | Data saving | Save as files | ||
| 10 | Curves type | X-coordinate: total time, charge discharge capacity, cycle time | ||
| Y-coordinate: total voltage, current, capacity, power, cell temperature | ||||
| 11 | Software protection | Power off data protection, power resume continue testing, OVP, ODP, OCP, UCP, OTP, capacity protection, abnormal voltage trend protection, abnormal current trend protection, abnormal current fluctuation protection, abnormal voltage fluctuation protection, abnormal charging voltage increase rate protection, abnormal discharge current decrease rate protection | ||
| Hardware protection | Power off, open circuit and short circuit protection. Reverse or wrong connection protection, OCP, OVP, OTP. | |||
| Warning function | Switch off automatically under emergency, shutdown when power off, load connect and disconnect automatically. | |||
| 12 | Sampling terminals | Four-polar sampling. Crocodile clip or other clips. | ||
| 13 | Energy consumption | Discharge power feedback to grid | ||
| 14 | Cooling method | Forced Fan-cooled | ||
| 15 | Safety grade | In accordance with EN60950, GB4943 | ||
| Voice | Test voice by IEC62040-3 and voice is less than 70dBA. Sound level meter should be accordance with Ⅰtype in IEC804, Accuracy should be better than ±0.5dB. | |||
| IP grade | IP20 | |||
| Thunder proof | Reach GB17626 2-pole lightning protection requirements. | |||
| 16 | Repair | Modularized structure. Can be replaced or repair with spare parts. Free during warranty period. | ||
| 17 | Software update | For lifetime until hardware incompatible. | ||
Advantages
- Power feedback to grid with direct current bus efficiency ≥60%: Both charging and discharging is energy-saving which saves a lot of electric power expenses and air-conditioner fees.
- Channels can be connected in parallel: Channels can be connected in parallel to increase current testing range, through which current would be doubled by increasing quantity of channels. For example, if 2 channels of 5V100Aequipment are connected in parallel, output current can be as much as 5V200A, and also fulfill accuracy requirement, which can save cost and resources.4channels can be connected in parallel at most.
- CCCV charge: CC charge transfer to CV charge smoothly, without any impact, which can avoid the micro-shot circuit due to high temperature of peak current impact or to avoid PCB protection or second protection action caused by over-charging.
- Current soft start to avoid any impact.
- Current and voltage sampling is of high stability and accuracy: this equipment applied 16bit bipolar ADC/DAC unit, to ensure voltage sampling high accuracy and long-term stability.
- DCIR test function: Pick out the DC load resistance unstable cell, to avoid repeated test caused by poor contact terminals or terminal oxidation due to long time use.
- Dynamic load protection DL function: this insures no large current go through cause by bad connection, to protect efficiently battery, PCB, MOSFET or FUSE from damage.
- Voltage clamp function: when battery does protect action through charging process, voltage clamp to pre-set voltage can protect battery or PCB from damage.
- ECD & EVD protection: avoid battery active protection and stop charging or discharging in advance caused by substandard conditions.
- Testing steps can set record conditions by section to achieve intelligent data management.